Cell Ranger7.0, printed on 11/21/2024
This tutorial introduces the cellranger multi pipeline for Cell Ranger 6.0+ (we recommend completing the other tutorials in this series first).
In this tutorial, you will learn how to:
This tutorial is written with Cell Ranger v7.0.0. Commands are compatible with other versions of Cell Ranger, unless noted otherwise. |
In this tutorial, we will analyze a 3' Cell Multiplexing dataset that consists of two cell lines, Jurkat and Raji, multiplexed at equal proportions with one CMO per cell line, resulting in a pooled sample labeled with two CMOs. Gene Expression (GEX) and Cell Multiplexing libraries were prepared with the Chromium Next GEM Single Cell 3ʹ Reagent Kits v3.1 (Dual Index) with Feature Barcode technology.
Use wget to download the FASTQ data (about 44 GB):
wget https://cg.10xgenomics.com/samples/cell-exp/6.0.0/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_Multiplex/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_Multiplex_fastqs.tar
Download and untar the 2020 reference, if you have not already done so in the count tutorial:
wget https://cf.10xgenomics.com/supp/cell-exp/refdata-gex-GRCh38-2020-A.tar.gz tar -xf refdata-gex-GRCh38-2020-A.tar.gz
Untar the FASTQ files:
tar -xf SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_Multiplex_fastqs.tar
Navigate to the FASTQ files and observe their filenames. There is one directory that contains the FASTQ files for the GEX library. There are two that contain FASTQ files for the Cell Multiplexing Capture library because the same physical library was sequenced twice for this particular dataset - first for a preliminary sample quality check and second for the actual analysis.
The simplest scenario is to analyze one Gene Expression and one Multiplexing Capture library, which we will demonstrate using the FASTQ files in the ..._1_gex
and ..._1_multiplexing_capture
directories.
. ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L001_I1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L001_I2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L001_R1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L001_R2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L002_I1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L002_I2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L002_R1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L002_R2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L003_I1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L003_I2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L003_R1_001.fastq.gz │ └── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex_S2_L003_R2_001.fastq.gz ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L001_I1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L001_I2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L001_R1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L001_R2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L002_I1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L002_I2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L002_R1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L002_R2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L003_I1_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L003_I2_001.fastq.gz │ ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L003_R1_001.fastq.gz │ └── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture_S1_L003_R2_001.fastq.gz └── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_2_multiplexing_capture ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_2_multiplexing_capture_S1_L001_I1_001.fastq.gz ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_2_multiplexing_capture_S1_L001_I2_001.fastq.gz ├── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_2_multiplexing_capture_S1_L001_R1_001.fastq.gz └── SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_2_multiplexing_capture_S1_L001_R2_001.fastq.gz
The cellranger multi pipeline has two inputs:
--id
is used to name the output directory that the pipeline runs in.--csv
takes a CSV file that points to the FASTQ files, and contains other parameters from the
cellranger
multi pipeline.In this tutorial, you only need to edit a few lines in a pre-made CSV using a text editor of your choice, in this example with nano:
nano SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K.csv
Copy and paste the code block below into your text editor. For this example, there are three sections: [gene-expression]
, [libraries]
, and [samples]
. Important: replace the /path/to/ text with the full paths to the reference (in [gene-expression]
section) and FASTQ files (in [libraries]
section) that you downloaded before saving the CSV file.
For a full list of the different sections, fields, and optional parameters, please see the running cellranger multi page.
[gene-expression] ref,/path/to/refdata-gex-GRCh38-2020-A [libraries] fastq_id,fastqs,lanes,feature_types SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex,/path/to/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex,any,Gene Expression SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture,/path/to/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture,any,Multiplexing Capture [samples] sample_id,cmo_ids,description Jurkat,CMO301,Jurkat Raji,CMO302,Raji
[libraries]
section for the 2nd sequence run:
[libraries] fastq_id,fastqs,lanes,feature_types SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex,/path/to/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K/ SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_gex,any,Gene Expression SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture,/path/to/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_1_multiplexing_capture,any,Multiplexing Capture SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_2_multiplexing_capture,/path/to/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K/SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K_2_multiplexing_capture,any,Multiplexing Capture
Next run the cellranger multi command with --help
to get the usage and a full list of modifiable parameters.
cellranger multi --help
The output looks similar to this:
cellranger-multi Analyze multiplexed data or combined gene expression/immune profiling/feature barcode data USAGE: cellranger multi [OPTIONS] --id--csv OPTIONS: --id <ID> A unique run id and output folder name [a-zA-Z0-9_-]+ --description <TEXT> Sample description to embed in output files [default: ] --csv <CSV> Path of CSV file enumerating input libraries and analysis parameters --dry Do not execute the pipeline. Generate a pipeline invocation (.mro) file and stop ...
To run cellranger multi, enter a command such as:
cellranger multi --id=Jurkat_Raji_10K --csv=SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K.csv
Cell Ranger 6.0+ should start with a message like this:
Martian Runtime - v4.0.8 Running preflight checks (please wait)...
Depending on your computational resources, it may take some time for the pipeline to complete. When it does, it should conclude with a message like this:
Waiting 6 seconds for UI to do final refresh. Pipestance completed successfully! 2022-05-09 19:20:44 Shutting down.
Next, examine the output files using the tree command:
cd Jurkat_Raji_10K/outs tree
The tree command will list 73 directories with 96 files. (If you are used to a cellranger count run, recall that multiplexing two samples necessitates doubling the per-sample outputs, and these numbers will grow correspondingly as more samples are multiplexed into a single GEM well). Additionally, there are some output files that are general to the entire experiment rather than a specific CMO.
The first section of the outputs contains the config.csv
file, a duplicate of the input config CSV (SC3_v3_NextGem_DI_CellPlex_Jurkat_Raji_10K.csv
). The multi
directory contains a count
directory and a multiplexing_analysis
directory:
└─ config.csv └─ multi ├── count │ ├── feature_reference.csv │ ├── raw_cloupe.cloupe │ ├── raw_feature_bc_matrix │ │ ├── barcodes.tsv.gz │ │ ├── features.tsv.gz │ │ └── matrix.mtx.gz │ ├── raw_feature_bc_matrix.h5 │ ├── raw_molecule_info.h5 │ ├── unassigned_alignments.bam │ └── unassigned_alignments.bam.bai └── multiplexing_analysis ├── assignment_confidence_table.csv ├── cells_per_tag.json ├── tag_calls_per_cell.csv └── tag_calls_summary.csv
For more information on these files, see Cell Multiplexing Outputs.
The per_sample_outs
directory contains two directories, one for Jurkat
and one for Raji
. For brevity, only the Jurkat outputs are shown here.
In the Jurkat/count/analysis
directory, the clustering
directory contains CSV files with the results of graph-based clusters and K-means clustering from 2-10:
└─ clustering ├── graphclust │ └── clusters.csv ├── kmeans_10_clusters │ └── clusters.csv ├── kmeans_2_clusters │ └── clusters.csv ├── kmeans_3_clusters │ └── clusters.csv ├── kmeans_4_clusters │ └── clusters.csv ├── kmeans_5_clusters │ └── clusters.csv ├── kmeans_6_clusters │ └── clusters.csv ├── kmeans_7_clusters │ └── clusters.csv ├── kmeans_8_clusters │ └── clusters.csv └── kmeans_9_clusters └── clusters.csv
The diffexp
directory likewise contains CSV files with the results of differential expression analysis between the clusters reported above:
└─ diffexp ├── graphclust │ └── differential_expression.csv ├── kmeans_10_clusters │ └── differential_expression.csv ├── kmeans_2_clusters │ └── differential_expression.csv ├── kmeans_3_clusters │ └── differential_expression.csv ├── kmeans_4_clusters │ └── differential_expression.csv ├── kmeans_5_clusters │ └── differential_expression.csv ├── kmeans_6_clusters │ └── differential_expression.csv ├── kmeans_7_clusters │ └── differential_expression.csv ├── kmeans_8_clusters │ └── differential_expression.csv └── kmeans_9_clusters └── differential_expression.csv
The pca
, tsne
, and, umap
directories contain CSV files for dimensionality reduction:
├── pca │ └── 10_components │ ├── components.csv │ ├── dispersion.csv │ ├── features_selected.csv │ ├── projection.csv │ └── variance.csv ├── tsne │ ├── 2_components │ │ └── projection.csv │ └── multiplexing_capture_2_components │ └── projection.csv └── umap ├── 2_components │ └── projection.csv └── multiplexing_capture_2_components └── projection.csv
The remaining per_sample_outs
are described in the Cell Multiplexing Outputs.
├── sample_cloupe.cloupe │── feature_reference.csv │── sample_alignments.bam │── sample_alignments.bam.bai │── sample_filtered_barcodes.csv │── sample_filtered_feature_bc_matrix │ ├── barcodes.tsv.gz │ ├── features.tsv.gz │ └── matrix.mtx.gz │── sample_filtered_feature_bc_matrix.h5 │── sample_molecule_info.h5 │── metrics_summary.csv └── web_summary.html
Starting with Cell Ranger v.7.0, Single Cell Fixed RNA Profiling datasets can be analyzed with the cellranger multi pipeline as well. For specific multi pipeline details and outputs, see:
Questions or feedback about this tutorial? Contact [email protected].